BUILDING SCIENCE · STEP CODE

Airtightness is measured, not promised.

Under the BC Energy Step Code, a new home is tested with a blower door and the result is checked against the target for its step. The number belongs to the whole building. Framing, windows, and every mechanical, electrical and plumbing penetration play a part. Most of it is won or lost at the air barrier, and the air barrier is our work.

How the test works.

The Energy Advisor sets a fan in an exterior door and pulls air out of the house until it holds a set pressure. The air the fan has to move to hold that pressure shows how much the building leaks. Your Energy Advisor decides how the house is prepared for the test and confirms the target and the metric that apply to your project.

Test before the drywall.

On our jobs, the mid-construction test typically happens once the interior vapour barrier is done and before the drywall goes up. That way the exterior air barrier and the interior vapour barrier are checked together, and a leak in either one is still easy to find, reach and fix. We recommend booking one on every Step Code build.

What has to be finished first.

The exterior air barrier continuous and taped at every lap and seam. Windows and doors installed and sealed to it. Every penetration through the wall sealed. The interior vapour barrier complete. Temporary openings closed.

Built for the test.

We install the air barrier, seal its transitions and keep it whole while the insulation and cladding go on. We work with your Energy Advisor and the other trades, so nobody cuts the barrier and patches it after we have left.

Step Code by municipality.

Requirements differ across the Okanagan. The table below shows the current step for each community, with its sources. Confirm the requirement with the building department and your Energy Advisor before you price or build.

  • Since 2023-05-01, most new Part 9 buildings in BC must meet at least Step 3 of the BC Energy Step Code; Step 3 for Part 9 and Step 2 for Part 3 are the province-wide minimum. (S1)
  • Since 2025-03-10, the Province requires most new buildings to meet at least level EL-1 (measure only) of the Zero Carbon Step Code. (S3)
  • A mid-construction airtightness test is not required across the province; some local building departments require or encourage one. (S4)
  • The Province's stated goal is net-zero energy ready new construction by 2032, reached through gradual increases in the BC Building Code's energy requirements. (S1, S2)
Part 9 airtightness levels by step (maximum values; meeting any one metric is enough)
StepAirtightness levelACH50NLR50 (L/s per m²)NLA10 (cm² per m²)
Step 3AL-12.50.891.20
Step 4AL-31.50.530.72
Step 5AL-41.00.350.48

Source: S5, the Revision 5 change document. Your Energy Advisor confirms the target and the metric (ACH50, NLR50 or NLA10) that applies to your project; smaller homes can often be assessed on NLR50 or NLA10.

Part 9 Energy Step Code and Zero Carbon Step Code, Okanagan municipalities
MunicipalityEnergy Step Code (Part 9)Zero Carbon Step CodeSources
City of Kelowna Step 3, since 2021-06-01. No local level found; the provincial EL-1 floor applies. S21, S3
A mid-construction airtightness test is not required.
City of West Kelowna Step 3, in effect since 2023-05-01 (the provincial change). Not mentioned on the City page; the provincial EL-1 floor applies. S12, S3
District of Lake Country Step 3 (the province-wide floor since 2023-05-01). No local level found; the provincial EL-1 floor applies. S1, S13, S3
City of Vernon Step 3 for all Part 9 residential buildings, since 2023-01-01 (Building Bylaw 5900, s. 15.3(b)). EL-1 (measure only), Bylaw 5993 adopted 2024-04-22. S15
City of Penticton Step 3 minimum, since 2021-01-01. No local level found; the provincial EL-1 floor applies. S16, S22, S3
A mid-construction blower-door test is required: the Energy Advisor's mid-construction test and compliance report goes in before the insulation and vapour barrier inspection (Building Bylaw 2021-21).
District of Summerland Step 3, since 2022-09-01. EL-1 since 2025-03-10 through the provincial order (the District had not yet added the Zero Carbon Step Code to its own building bylaw). S17
District of Peachland Step 3 equivalent for Part 9 (Step 2 equivalent for Part 3), since 2023-05-01. Not mentioned; the provincial EL-1 floor applies. S18, S3

Send the drawings.

Send the drawings and the Step Code target. We price the air barrier and envelope scope to it.